Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
Skip to Content
EZ
GC &
EZ
LC Online Software Suite
My Account
Register for Free
Sign In
Restek Home
Pro
EZ
GC Chromatogram Modeler
Pro
EZ
LC Chromatogram Modeler
EZ
GC Method Translator & Flow Calculator
Pro
EZ
LC Method Translator
N-Nitrosodimethylamine
CAS # 62-75-9
Find another compound
Begin typing and choose a compound from the list, then click "Select."
Compound Structure and Properties
Molecular Weight
74.0818
Formula
C
2
H
6
N
2
O
Boiling Point
153 °C, 426.2 °K, 307 °F
Density
1.005 g mL
−1
Solubility in Water
290 mg mL
−1
(at 20 °C)
log P
−0.496
Data above sourced from:
ChemSpider
and
Wikipedia
GC Mass Spectrum
m/z
Click and drag to zoom, double click to reset zoom
Hover over end of line for value.
Synonyms
N-Nitrosodimethylamine; Methanamine, N-methyl-N-nitroso-; Dimethylamine, N-nitroso-; Dimethylnitrosamine; DMN; DMNA; N-Nitroso-N,N-Dimethylamine; (CH3)2NNO; Dimethylnitrosamin; Dimethylnitrosoamine; N-Methyl-N-nitrosomethanamine; N,N-Dimethylnitrosamine; NDMA; Nitrosodimethylamine; Rcra waste number P082; 1,1-Dimethyl-2-oxohydrazine; NSC 23226; n-Nitrosodiméthylamine; N-nitrosodimetilammina
Related Products
SVOC MegaMix 150 Kit, 1 mL/ampul; 6 ampuls/kit
8270 MegaMix Standard, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270/Appendix IX Kit
SV Calibration Mix #3, 2000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Calibration Kit, 2000 µg/mL
SVOC MegaMix 100 Kit, 1 mL/ampul; 3 ampuls/kit
8270 Calibration Mix #2, 2000 µg/mL, Methylene Chloride:Methanol (85:15), 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul
Semivolatiles MegaMix Standard, EPA Method 625, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
607 Calibration Mix, Nitrosamines, 2000 µg/mL, Methanol, 1 mL/ampul
N-Nitrosodimethylamine Standard, 1000 µg/mL, Methanol, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 5 mL/ampul, 15-pk.
Semivolatile Calibration Kit #3 (with Benzidine)
Nitrosamine Calibration Mix, Method 521, 1000 µg/mL, Methylene Chloride, 1 mL/ampul
8270 Matrix Spike Mix, 200 µg/mL, Methanol:Methylene Chloride (80:20), 10 mL/ampul
Nitrosamines 7 Standard, 100 µg/mL in Acetonitrile, 1 mL/ampul
Application Chromatograms
Nitrosamines 7 Standard on Rxi-624Sil MS
Nitrosamines 7 Standard on Raptor C18
Comparison of Conventional and LPGC-MS (0.53 mm ID) Analysis of Nitrosamines
Comparison of Conventional and LPGC-MS (0.32 mm ID) Analysis of Nitrosamines
Comparison of Conventional and LPGC-MS Analysis of Nitrosamines
Conventional GC-MS Analysis of Nitrosamines on Rxi-624Sil MS
Semivolatiles SVOC MegaMix 100 Kit on Rxi-SVOCms
Semivolatiles SVOC MegaMix 150 Kit on Rxi-SVOCms
Semivolatiles on Rxi-SVOCms
Semivolatiles Analysis on Rxi-SVOCms
Nitrosamines on Rxi-624Sil MS
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
Combination Run of U.S. EPA Methods 521 and 522, Nitrosamines and 1,4-Dioxane, on Rxi-5Sil-MS by CSR-LVSI
50 µL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
10 μL CSR-LVSI with 5 ng Nitrosamines, THF, and 1,4-Dioxane On-Column
0.50 ng/L N-Nitrosodimethylamine (NDMA) Laboratory Fortified Drinking Water Sample Extract on Rxi-5Sil MS
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Nitrosamines by U.S. EPA Method 607 on Rtx-5
Nitrosamines in Drinking Water on Rxi-624Sil MS by Modified EPA Method 521 Utilizing CSR-LVSI
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Nitrosamines on Stabilwax-DB
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)